Main Features
• Four hardwire zone addition capacity
• Fail-safe and fail-secure option
• Supervised by panel for wire tamper
• On-board cover and wall tamper detection
• FLASH firmware upgradeable
• LED status and problem indicator
• Eight different options to connect wired detectors
PROFESSIONAL GRADE FEATURES
• Compatible with Rosslare’s AuraSys P6 wired
control panel and other MatrixBus accessories
• Cost effective and modular installation anywhere
on the bus near the devices to be controlled
• Jumper selectable zone addressing

Compare
Category: Tags: , , , , , , , , , , , , , ,
   

Share this product

MatrixBus XI-4 expansion is one of a highly advanced line of expansion modules
that work seamlessly with the AuraSys™ system, ideal for residential and commercial
applications. The XI-4 packs features such as state-of-the-art communication with the panel
and an LED status indicator. The MatrixBus XI-4 expansion adds flexibility to the AuraSys
panel by increasing zone coverage by an additional four hardwired zones.
The unit comes in double tamper protected housing and is easy to install anywhere on the bus
that is connected to the panel.

Overview

MatrixBus XI-4 expansion is designed with a
focus on high quality and reliability as our top priority.
Easy to install and operate, the MatrixBus XI-4
expansion features state-of-the-art supervised
communications with the panel.
By connecting the expansion to the MatrixBus, four
hardwired zones are added to the AuraSys panel zone
coverage. Four-zone and eight-zone modules may be
combined as necessary to supply the required number
of zones.
The casing includes cover and back tamper detection to
prevent vandalism and unauthorized access to the PCB
casing as well as a status LED.
The MatrixBus XI-4 expansion zones have the same
characteristics as the on-board zones without the
doubling option.

Specifications

ELECTRICAL SPECIFICATIONS
• Zone capacity Four
• Auxiliary voltage from bus 13.4 – 13.8 VDC
• Maximum input current 35mA
• Indication Green LED
ENVIRONMENTAL SPECIFICATIONS
• Operating environment Indoor use only
• Operating temperature -10°C to 50°C (14°F to 122°F)
• Operating humidity 0% to 95% (non-condensing)
PHYSICAL SPECIFICATIONS
• Dimensions (H x W x D) 101 x 99 x35 mm (4 x 3.9 x 1.4 in); fits US gang box
• Weight 138.5 g (0.305 lbs)