The ME-00 offers a rack which can hold several MUs, EUs or a
combination of both.
ME00+031 Boards Tray Cabinet Housing
ME-00+031 Boards Tray Cabinet Housing
The rack holds one 14 Ah backup battery
as well as a power supply which powers all the connected
units.
Description
Overview
Overview
To wire the ME-00 Boards Tray Cabinet Housing:
1. Connect a 12-16VDC 1500mA transformer to the power
terminal block.
2. Connect the backup battery to the battery terminal block.
3. Connect a tamper switch to the tamper input terminal
block
Shipping & Delivery
Related products
AURA – P6 – Remote 16-zone MatrixBus™
Zone Indicators
A maximum of sixteen zones are possible: 6 on board, 12 on
board with doubling and 16 with an additional expansion
module. The indicators can blink (indicating an open sensor
condition) or be on permanently (when the zone is violated) or
be off, depending on the status or mode or operation of the
system.